Dual Channel Digital Controller TTM-509 Specification
* The above product colors (optimized for our web sites) may not be equal to actual ones.
Feature
High accuracy, High speed sampling cycle
High accuracy ±0.1%, high speed sampling cycle: 50ms
Variety inputs
2 inputs can be equipped upon request and variety of input type 1/100°C can be indicated for 4 wires RTD and RTD
The various controls can be performed per unit.
2 inputs control, cascade control, remote SP, positioning proportional control and so on are selectable by parameters setting.
SD card available
The data log function for recording measurement values and various statuses is installed. The stored data is taken into personal computer and it is readable by EXCEL etc.
Variety outputs
Main control outputs and event outputs can be allocated into multiple functions. (Main outputs: 2, auxiliary outputs: 4)
MODBUS protocol available
The current TTM protocol and MODBUS protocol additionally available
Infrared communication function equipped
Wireless communication can be performed by using infrared.
2ch CT input
The disconnection under three-phase circuit wires can be detected by using 2ch CT input.
Memory bank function
8 types of control parameters can be stored which is changed by DI and communication.
Self-tuning PID (Heating/Cooling)
The optimum PID constant against control object is automatically calculated. PID constant is calculated when making alteration of setting value, or it is corrected when disturbance/hunting etc occurred.
Blind function
At the request, desirable parameter screen is only displayed and set up.
Simplified timer
ON/OFF setting control is available after some certain interval. Function of ON/OFF alarm output is independently usable.
Priority display
Demanding parameter screens are monitored and set up under operational mode screen. (max. 36 screens)
Multiple inputs
Thermocouple, RTD, voltage, current (1 to 5VDC shunt resistance 250ohm) Types of input can be changed by parameter setting.
Key allocation function
AT start/stop, RUN/READY, Timer start/stop, Event start/stop and etc can be allocated into [FUNC1] [FUNC2] [FUNC3].
Deviation monitor function
The deviation status can be checked in front monitor.
Manual control (Balance-less & Bump-less)
Manual output function is applicable for versatile applications of instrumentation systems.
Digital PV filter
For abrupt alteration of input value, filter effect is operational on software.
PID over-shoot protection
It is functional to inhibit PID over-shoot.

Please download and look at a catalog for details.